Vacuum Interrupter HCJ5 1.14kv 1000A for vacuum contactor
Vacuum Interrupter HCJ5 1.14kv 1000A for vacuum contactor
HCJ5 1.14kv 1000A vacuum interrupter for vacuum contactor
1. Brief introduction
The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environmen
2. Vacuum Tube main technical parameter
Rated voltage: 1.14 kv
Rated current: 1000 A
Rated put through current: 10000A
Rated breaking current: 8000A
Limiting breaking current: 10000A
Rated short-time withstand current: 8000A
Rated short-time withstand voltage(1 min): 10 kv
Mechanical life: 1000000 times
Rated breaking time AC3: 150000 times
Rated breaking time AC4: 6000 times
Automatic closing force of the contacts: 70±20 N
Force required to hold contacts open at full stork: 90±20 N
Contact automatic blocking ability loop electrical resistance: ≤80μΩ
Contact-wear allowance thickness: 2 mm
Shelf life: 20 years
Internal gas pressure: ≤1.33×10-3 Pa
No. | Parameter name | Unit | Value | |
1 | Rated voltage | kV | 1.14 | |
2 | Rated current | A | 1000 | |
3 | Rated frequency | Hz | 50 | |
4 | Rated put through current | A | 10000 | |
5 | Rated breaking current | A | 8000 | |
6 | Limiting breaking current | A | 10000 | |
7 | Rated short-time withstand current | A | 8000 | |
8 | Rated short-time withstand voltage(1 min) | KV | 10 | |
9 | Mechanical life | time | 1000000 | |
10 | Rated breaking time | AC3 Series | time | 150000 |
AC4 Series | 6000 | |||
11 | Automatic closing force of the contacts | N | 70±20 | |
12 | Force required to hold contacts open at full stork | N | 90±20 | |
13 | Contact automatic blocking ability loop electrical resistance | μΩ | ≤80 | |
14 | Contact-wear allowance tickness | mm | 2 | |
15 | Shelf life | year | 20 | |
16 | Internal gas pressure | Pa | ≤1.33×10-3 |
Strong package, Safety first.
As long as possible to keep the products safe until it arriving customer's warehouse.
Clearly marking label outside of package, customers will be easy to identify their goods.
Vacuum Interrupter Workshop
Design the Vacuum Interrupter for you.
VCB Production Line
VCB Production Line
- Tel
- *Title
- *Content
Professional production line solution provider!
Sign up today for hints, tips and the latest product news - plus exclusive special offers.
Tel:+0086-18131539058
We don’t do spam and Your mail id is very confidential.