MAIN TECHNICAL DATA (FOR LOAD-BREAKING SWITCH)
Items |
Data |
Rated voltage |
40.5KV |
Rated current |
1250,630A |
Rated frequency | 50/60Hz |
Short-time (1 min) power -frequency withstand voltage | *95KV |
Lightning impluse withstand voltage (peak) | *185KV |
Rated short-circuit making curremt | 32KA |
Rated peak withstand current | 32KA |
Rated short -time withstand current(4s) | 12.5KA |
Rated closed circuit breaking current | 630A |
Rated transfer current | 2000A |
Rated load with power breaking current | 1250A |
Rated cable-charging breaking current | 10A |
Circuit resistance at minimum added force | ≤40μΩ |
Mechanical life | 10000 times |
Closing force due to bellows and atmosphere | 135±50N |
Force required to hold contacts open at full stroke | 210±50N |
Contact erosion limit | 3mm |
Shelf life | 20 years |
Total mass of interrupter/Moving mass of interrupter | 3.39Kg/0.8Kg |
MACHANICAL DATA OF SWITCH RECOMMENDATIONS WITH THE INTERRUPTERS
Items |
Value |
Rated contact stroke | 17±1mm |
Contact connection stroke | 4±1mm |
Average opening speed(0-8mm stroke) | 1.6±0.2m/s |
Average closing speed(8mm-contact making) | 0.8±0.2m/s |
Added force on closed contacts | 1000±200N |
Max. bouncing duration | ≤5ms |
Out of simultaneity of contact closing and opening |
≤2ms |
Max. rebound distance |
≤2mm |
Max. overtravel | ≤2mm |
Note:
With insulation cover
Packing & Delivery

Strong package, Safety first.
Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.
As long as possible to keep the products safe until it arriving customer's warehouse.
Clearly marking label outside of package, customers will be easy to identify their goods.
As long as possible to keep the products safe until it arriving customer's warehouse.
Clearly marking label outside of package, customers will be easy to identify their goods.
Our Company

Pro20000 M2 of JUCRO Electric company land

1500 M2 of office building

5000 M2 of workshop building

Inside of JUCRO Electric office building

Inside of JUCRO Electric office building

JUCRO Electric office work area
Workshop

Vacuum Interrupter Workshop
Accept customized order.
Design the Vacuum Interrupter for you.
Design the Vacuum Interrupter for you.

VCB Production Line
VCB Vacuum Circuit Breaker production Line.

VCB Production Line
VCB Vacuum Circuit Breaker production line, Engineers routine inspection.
Quality Inspection

Carefully inspection of each product, Quality guaranteed

completely data records of entire process , all the product data can be traced.
Related Products
Please send your message to us
- Tel
- *Title
- *Content
Professional production line solution provider!
MOBILE WEB

Company
Categories
NEWSLETTER
Sign up today for hints, tips and the latest product news - plus exclusive special offers.

Tel:+0086-18131539058
subscription
We don’t do spam and Your mail id is very confidential.