Load Switch-fuse Combination FKN12A-12(D)/T630-20 FKRN12A-12(D)/T125-31.5 AC high voltage gas production load switch/High voltage
Load Switch-fuse Combination FKN12A-12(D)/T630-20 FKRN12A-12(D)/T125-31.5 AC high voltage gas production load switch/High voltage
Categories | Accessories for switchgear |
---|---|
Brand | JUCRO |
Model | FKN12A-12(D)/T630-20 FKRN12A-12(D)/T125-31.5 |
FOB port | SHANGHAI/NINGBO |
Terms of Payment | L/C, Western Union, MoneyGram, T/T |
Update Time | Nov 23,2024 |
F KN12A-12 (D )/T630-20 FKRN12A-12 (D )/T125-31.5 AC high voltage gas production load switch/High voltage load switch-fuse combination
FKN12A-12D gas production load switch, FKRN12A-12D series gas production load switch-fuse combination electric appliance, is a new series of switches and equipment developed by our company. It is suitable for 12KV and below three-phase power distribution system, as transformer, cable and overhead. It is used for the control and protection of power equipment such as lines; it is especially suitable for terminal substations and box-type substations in urban and rural networks. It is also suitable for the control and protection of ring networks and dual radiant power supply units.
FKN12A-12D series gas production load switch can divide load current and adoptive current.
This series of products has the characteristics of compact structure, reasonable design, reliable interlocking and high insulation level; The spring energy storage operating mechanism makes the opening and closing speed unaffected by the operator's operating force; The arc is extinguished in the bell-shaped insulating cover, and the free gas during arcing does not cause a decrease in the insulation strength between the phases or the ground. Adopting the arc-ignition needle and plum-shaped contact of copper-tungsten alloy, the switch is reliable in conduction and long in electrical life. This series of products is easy to maintain, easy to operate, reliable in operation, and won praise from users.
Working condition:
1. Ambient air temperature: -25 ℃-40 ℃;
2. The altitude should not over 1000mm;
3. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%;
4. The earthquake crack does not exceed 8 degrees;
5. No fire, explosion hazard, chemical corrosion and severe vibration;
6. Pollution level: class 2.
Main technical parameter
No. | Item | Unit | 参数 Parameters |
1 | Fracture opening | mm | ≥175 |
2 | Interphase center distance | 210±2 | |
3 | Interphase air gap | ≥125 | |
4 | travel | 210±4 | |
5 | Over travel | ≥40 | |
6 | Three-phase closing | ms | ≤0 |
7 | Three-phase opening | ≤5 | |
8 | Shunt release inherent breaking time | 40-65 | |
9 | Main loop resistance | μΩ | ≤130 |
Mechanical properties
No. | Item | Unit | FKN12A-12D | FKN12A-12D | ||
1 | Rated voltage | KV | 12 | 12 | ||
2 | Rated Frequency | Hz | 50 | 50 | ||
3 | Rated Current | A | 630 | 125 | ||
4 |
|
| On the groud | KV | 42 | 42 |
Fracture | 48 | 48 | ||||
| On the groud | 75 | 75 | |||
Fracture | 85 | 85 | ||||
5 |
| Load switch | KA | 20 | ||
Grounding switch | 20 | |||||
6 |
| Load switch | S | 4 | ||
Grounding switch | 2 | |||||
7 | Rated short circuit closing current (peak) | KA | 50 | |||
8 | Rated breaking current |
| A | 630 | ||
Closed loop breaking current | 630 | |||||
Cable charging current | 10 | |||||
| KVA | 1250 | ||||
9 |
| KA | 31.5 | |||
10 | Rated transfer current | A | 1200 | |||
11 | Mechanical life | Times | 2000 | 2000 |